Skip to main content

Table 1 Bioreactor configuration and applications

From: A modular flow-chamber bioreactor concept as a tool for continuous 2D- and 3D-cell culture

Bioreactor design

Potential applications

Example

I.

Single channel, 6 variable culture inserts for 3D scaffolds transparent cover plate

active aeration

Long term cultivation of 3D tissue constructs under flow conditions,

tissue cultivation on implantable biomaterials

Cultivation of cartilage-carrier constructs [2]

II.

4 flow channels for perfusion 24 well plate layout inserts for 3D scaffolds surface aeration gas supply from humidified incubator

Simultaneous cultivation of four 3D constructs per channel, 4 channels available, separate functional tests can be carried out on single constructs

3D cultures of liver cells [3], biomaterial testing

III.

As (II), transparent bottom plate for microscopy flow channels instead of separate wells

Cultivation of shear-responsive cells, integration of biomaterials possible (e.g. a collagen membrane)

Cultivation of sweat-gland associated cells (current)

IV.

As (II) plus integrated of electrodes for electrical stimulation and impedance measurement

Electrical stimulation of cell growth and orientation, impedance measurement of cell viability

Orientation of mitotic axis [5]