Skip to main content

Use of the Dynamic External Distractor Ligamentotaxor in finger trauma

Introduction

The treatment of fracture dislocations of the fingers is difficult.

The concept of capsuloligamentotaxis is familiar but the systems of external distraction are cumbersome.

The Suzuki system is ingenious but not devoid of complications.

Materials

We report results of a series of 35 fingers in 32 patients treated by the Ligamentotaxor® external distraction system.

Results

Twenty-five patients were operated in emergency following complex MCP, PIP and DIP fractures and 7 patients at more than one month following trauma due to neglected dislocation or complications of arthroplasty.

The duration of distraction was 6 weeks.

Associated osteosynthesis was performed in 3 cases. The mean follow-up was 36 months.

Grip strength was 85% of the contralateral side.

Active flexion was 75° and flexion deformity 20°.

Pain recorded using the VAS was 1.5 and quick DASH score was 17.

One patient had sepsis requiring premature removal of metalwork.

One patient disassembled the distraction system himself.

Bone union occurred in all cases.

Conclusions

Despite the imperfections of the results, we think that Ligamentotaxor® is not cumbersome, easy to assemble and useful in treatment of complex PIP finger fractures as well as other fractures or sequelae of dislocations and arthroplasty based on an effect of capsuloligamentous, tendinous and skin taxis.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Schoofs, M. Use of the Dynamic External Distractor Ligamentotaxor in finger trauma. BMC Proc 9 (Suppl 3), A49 (2015). https://doi.org/10.1186/1753-6561-9-S3-A49

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1753-6561-9-S3-A49

Keywords