4kg solid replaces 80L liquid cleaner – innovative cleaner system for automated instrument reprocessing
BMC Proceedings volume 5, Article number: P40 (2011)
Introduction / objectives
SolidSafe System, an innovative cleaner system, has been developed for automated instrument reprocessing, consisting of cleaning and neutralisation products to be operated with a dispenser. Sustainability, easy and safe handling are core system benefits in addition to necessary application features a cleaning agent should have.
The environmental footprint is strongly influenced by offering water-free solid chemistry in 4 kg capsules. This solid chemistry is diluted to a liquid concentrate on site which is dosed from washer-disinfectors (WDs) for the reprocessing of medical instruments. The waste of empty plastic is reduced by 96%. This system offers a 28 fold reduction of energy for transportation as water based products no longer have to be shipped to the customer site.
Methods
From an ergonomic perspective, chemicals in concentrated and solidified form are preferred to the current liquid system in the central sterile department (CSD) of hospitals as evidenced by a study by the German Insitute for Occupational Health and Saftey (IFA). With current liquid products supplied in 5 to 200L cans, the system minimizes change intervals as 1 solid capsule (4 kg) equals up to 80L of liquid concentrate.
Results
Easily installed in different CSD set ups, the dispenser measures and monitors the concentration via conductivity device and ensures that the product is only released for use in the WDs when the defined concentration is reached. Data on the batch productions of liquid concentrate is saved in the dispenser system and can be down loaded as needed.
Conclusion
The SolidSafe System is the first in Europe to offer a dispenser with high accuracy and reliability in combination with the solid and high concentrated cleaning products MetalClean and AlkalineClean and the neutralisation product NeutraPlus.
Disclosure of interest
None declared.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Stingl, C., Andermatt, S. 4kg solid replaces 80L liquid cleaner – innovative cleaner system for automated instrument reprocessing. BMC Proc 5 (Suppl 6), P40 (2011). https://doi.org/10.1186/1753-6561-5-S6-P40
Published:
DOI: https://doi.org/10.1186/1753-6561-5-S6-P40