Table 1 Comparison of the MycoSEQ® Mycoplasma detection kit and CytoCheck® kit.

From: Evaluation of three commercial kits for mycoplasma NAT assays: selection and quality improvement

 

KIT supplier

 

Parameters

MycoSEQ®

CytoCheck®

Priority

 

Applied Biosystems

Greiner

 

tested sensitivity

<10 CFU/ml

<10 CFU/ml

1

Species coverage

> 90

41 identified

2

Time to results

Same day

Same day

3

Contamination prevention

No post-amplification sample handling

post-amplification sample handling

4

Reagent price ratio per test

1

10

5

Equipment

Real-Time PCR 7500

PCR machine scanner

6

quantitation

yes

no